Common array manager

9. Choose Typical to install the full management software on the data host. 10. Click next to display the Review Selections Screen. The screen should show that the software to be installed is the Full Install. The screenshot shows the Common Array Manager Windows Review Selections Screen. It shows the installation type that you selected. 11.

Common array manager. SANtricity or Common Array Manager report a critical fault of Host IO Card has Failed (xx.66.1150). SANtricity or Common Array Manager report a critical fault of Host IO Card is Degraded (xx.66.1300). SANtricity or Common Array Manager reports a critical fault of One or More Volumes not on their Preferred Path (xx.66.1010).

The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring.

使用 GUI 管理阵列 《Sun Storage Common Array Manager 阵列管理指南,版本 6.9.0》 使用 sscs CLI 管理阵列 《Sun Storage Common Array Manager CLI Guide, Version 6.9.0》 故障排除信息和硬件更换过程 服务顾问,从 Sun Storage Common Array Manager GUI 启动 从固件版本 6.x 升级到 7.x “升级固件 ... The Sun Storage Common Array Manager (CAM) 6.10 Update release is available only for Solaris OS management hosts. Oracle’s Sun Storage Common Array Manager (CAM) 6.10 software that includes the fix for the following CVEs is supported only on Oracle Solaris 10 SPARC and x86 platforms. If you are running the CAM software on Windows or Linux ... Storage Common Array Manager 6.10 Update. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 …Sun Storage Common Array Manager supports these arrays: Sun Storage 6000 array series. StorageTek 2500 array series. StorageTek FlexLine array series. Sun Storage … Sun Storage Common Array Manager: How to Save an Array Configuration for Duplication or Restoration (Doc ID 1007142.1) Last updated on JANUARY 30, 2022. Applies to: Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest.

The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.0: Enhancements to Auto Service Request (ASR) functionality. Support for Sun StorageTek FLX240, FLX280, and FLX380 Arrays. vi Sun StorageTek Common Array Manager ユーザーズガイドオープンシステム用• 2010 年 2 月 FMS エージェントの構成 65 アレイの健全性の監視の有効化 67 アラームとイベントの監視 67 アラーム情報の表示 68 アラームの管理 70 アラームの承認 70 1 つまたは複数のアラーム ... These release notes cover the software released on the Sun StorageTek Common Array Manager Software 6.0.0 CD. The Release Notes consist of the following sections: Features in This ReleaseCommon controller and disk array management tasks. You can perform various tasks to manage SAS RAID disk arrays. Use the information in this section to manage your RAID disk arrays. Using the Disk Array Manager The disk array manager is the interface for performing various tasks with disk arrays. Preparing disks for use in SAS disk arrays … Sun Storage Common Array Manager: How to Save an Array Configuration for Duplication or Restoration (Doc ID 1007142.1) Last updated on JANUARY 30, 2022. Applies to: Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] Note - At the release of this document, there is currently no support for using the Common Array Manager to upgrade disk module and SAS-NEM firmware to a level that allows SAS-1 device coexistence with server modules with SAS-2 REMs.For more information on upgrading disk module and SAS-NEM firmware to a level that allows SAS-1/SAS-2 …Category filter: Show All (183)Most Common (3)Technology (42)Government & Military (46)Science & Medicine (41)Business (40)Organizations (52)Slang / Jargon (5) Acronym Definition CAM Camera CAM Computer-Aided Manufacturing CAM Camshaft CAM 7 CAM Camcorder (video source) CAM Complementary and Alternative Medicine CAM Camden …

This chapter describes performing general administrative tasks applicable to all arrays. It contains the following subsections: “Using the Browser Interface” on page 2 “Administering Storage Arrays” on page 11 “Administering User Accounts” on page 17. 1. Using the Browser Interfacevi Sun StorageTek Common Array Manager User Guide for the J4000 Array Family • August 2008 The Event Life-Cycle 67 Setting Up Notification for Fault Management 68 Configuring Array Health Monitoring 76 To Configure the FMS Agent 76 To Enable Health Monitoring for an Array 78 Monitoring Alarms and Events 80This document is designed to help clarify when a drive should be replaced, if this fault should be present on an array. Symptoms Include: SANtricity Storage Manager shows an alert for Impending Drive Failure Low Risk; Common Array Manager shows an alarm for Impending Drive Failure Risk Low (xx.66.1026) Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest.

Mylearners.

Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …Sun Storage Common Array Manager provides several storage profiles that meet most storage configuration requirements. By default, the New Volume wizard will allow you to select a default pool with its default profile of RAID-5 characteristics. The profiles that display are specific to the model of the array and the drives it supports. Sun StorageTek Common Array Manager Installation Software CD 提供了三个与安装 有关的向导:. GUI (Graphical User Interface,图形用户界面)软件安装程序 - 使您可以通过图 形用户界面向导安装一系列选定的应用程序,以支持本地或远程的管理主机。. CLI (Command-Line Interface ... Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest.1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet n.n.n.n. 3. After logging in, switch user …

Sun Storage 2530 Array - Version Not Applicable and later Sun Storage 6180 Array - Version All Versions and later Sun Storage 6580 Array - Version All Versions and later All Platforms Goal. This document reviews the procedures for collecting performance statistics from arrays that can be managed using Sun Storage Common …Sun Storage Common Array Manager (CAM) - Version 5.0 and later Information in this document applies to any platform. Symptoms. Common Array Manager (CAM) is generating an alarm for a fault against one of its registered arrays. CAM fails to report the appropriate description and grid code for the alarm. The details may look …This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of …Common Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.Common controller and disk array management tasks. You can perform various tasks to manage SAS RAID disk arrays. Use the information in this section to manage your RAID disk arrays. Using the Disk Array Manager The disk array manager is the interface for performing various tasks with disk arrays. Preparing disks for use in SAS disk arrays …Sun Storage Common Array Manager: How to Save an Array Configuration for Duplication or Restoration (Doc ID 1007142.1) Last updated on JANUARY 30, 2022. Applies to: Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A] ...The Sun StorageTek Common Array Manager CLI Guide describes the commands in the sscsCLI. Consult the hardware installation guide for your array for information about the initial physical installation of an array. Related Documentation In addition, the Sun StorageTek Common Array Manager includes the following online documentation:Select Sun Storage Common Array Manager Software 6.10, and download the software. For detailed MOS download steps, see the knowledge article “How to Download Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note - Each array should be managed by one CAM management host only.This article documents Sun StorageTek Flexline 380 (FLX380) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support …Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …

Sun StorageTek Common Array Manager Software Installation Guide, Version 6.5.0: HTML: PDF: Sun StorageTek Array Administration Guide, Version 6.6.0: PDF: Sun StorageTek Common Array Manager User Guide for Open Systems: HTML: PDF: Sun StorageTek Common Array Manager CLI Guide, Version 6.6.0: HTML: PDF: Sun …

Sun StorageTek Common Array Manager CLI Guide sscs man pages. Preface xiv Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content,Sun StorageTek Common Array Manager Software Installation Guide, v6.1. HTML. PDF. Sun StorageTek Common Array Manager CLI Quick Reference, v6.1. PDF. Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version 6.1.2. HTML. PDF.This URL seems to be what you want: Installing the Typical Full Management Software. But having said that - you may want to look at a newer and more …Feb 21, 2023 · This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of verifying component ... From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page. (Doc ID 1012806.1) Last updated on MARCH 24, 2021. Applies to: . Sun Storage Common Array Manager (CAM) - Version 5.0 and later. All Platforms. Goal. …Storage Common Array Manager 6.8.1. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training forNote - At the release of this document, there is currently no support for using the Common Array Manager to upgrade disk module and SAS-NEM firmware to a level that allows SAS-1 device coexistence with server modules with SAS-2 REMs.For more information on upgrading disk module and SAS-NEM firmware to a level that allows SAS-1/SAS-2 …

Mailornage.

Maps of scottsdale.

Download popular programs, drivers and latest updates easily No specific info about version 6.9. Please visit the main page of Sun Storage Common Array Manager CLI on Software Informer.Most people looking for Common array manager downloaded: Sun Storage Common Array Manager Online Help. Download. One Interface, Run-Anywhere Flexibility Now there's an easy way to manage your storage environment. Similar choice › Download common view exe free › Gnu common lisp 2.4.9 free download;2. Instructions to download Common Array Manager (CAM). Method 1 - Searching with the MOS patch number: Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download.Sun StorageTek Array Administration Guide For Sun StorageTek Common Array Manager, Release 6.2: PDF: Sun StorageTek Common Array Manager CLI Guide, Release 6.2.0: HTML: PDF: Sun StorageTek Common Array Manager CLI Guide for the J4000 Array Family: HTML: PDF: Sun StorageTek Common Array Manager User … From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page. Look for the StorageTek Common Array Manager (CAM) Software release 6.1.2 or later. Using CAM With Disk Blades and Virtualized Multi-Fabric 10GbE NEM. CAM provides both a browser and command-line interface. When using the browser interface, you set up user accounts. When an authorized user logs in, information is laid out in pages.(Doc ID 1012806.1) Last updated on MARCH 24, 2021. Applies to: . Sun Storage Common Array Manager (CAM) - Version 5.0 and later. All Platforms. Goal. …%Program Files%\Sun\Common Array Manager\Component\sscs\bin. Volumes Supported on the Sun StorageTek 6130 Array up to 1022 . Bug 6540170 - Common Array Manager can be used to create up to 1022 volumes (volumes 0 through 1021) on the Sun StorageTek 6130 array. However, if the Access LUN is in use, up to 1023 volumes (volumes 0-1022) … ….

From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page.Category filter: Show All (183)Most Common (3)Technology (42)Government & Military (46)Science & Medicine (41)Business (40)Organizations (52)Slang / Jargon (5) Acronym Definition CAM Camera CAM Computer-Aided Manufacturing CAM Camshaft CAM 7 CAM Camcorder (video source) CAM Complementary and Alternative Medicine CAM Camden …The Sun StorageTek Common Array Manager CLI Guide describes the commands in the sscsCLI. Consult the hardware installation guide for your array for information about the initial physical installation of an array. Related Documentation In addition, the Sun StorageTek Common Array Manager includes the following online documentation:%Program Files%\Sun\Common Array Manager\Component\sscs\bin. Volumes Supported on the Sun StorageTek 6130 Array up to 1022 . Bug 6540170 - Common Array Manager can be used to create up to 1022 volumes (volumes 0 through 1021) on the Sun StorageTek 6130 array. However, if the Access LUN is in use, up to 1023 volumes (volumes 0-1022) … Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. Sun Storage Flexline 380 Array Sun Storage Common Array Manager (CAM) - Version: 5.0 and later [Release: 5.0 and later] Sun Storage 6180 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Storage 6780 Array - Version: Not Applicable to Not Applicable [Release: N/A to N/A] iv Sun StorageTek Common Array Manager CLI Guide • September 2009 Commands Used 21 Sample Data 21 Command Sequence 21 3. Monitoring and Administration Commands for All Arrays 27 add notification 27 Synopsis 27 Description 28 Options 28 Examples 29 add registeredarray 29 Synopsis 29 Description 29 Options 30 Examples 30Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest.Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. There are several components of the Sun StorageTek[TM] Common Array Manager (CAM) software : Solaris Web Console(SWC) Browser/Remote sscs interface(BUI/CLI) Fault Management Service(FMS) Common array manager, [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1], [text-1-1]